AJP Legacy  AJP: Regulatory, Integrative and Comparative Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol 231: 204-208, 1976;
0002-9513/76 $5.00
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pitlick, P.
Right arrow Articles by Friedman, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pitlick, P.
Right arrow Articles by Friedman, W.
American Journal of Physiology, Vol 231, Issue 1, 204-208
Copyright © 1976 by American Physiological Society


ARTICLES

Distribution of fetal cardiac output: importance of pacemaker location

PT Pitlick, SE Kirkpatrick, and WF Friedman

Important questions exist about the relative roles of changes in heart rate versus extent of myocardial shortening in regulating fetal cardiac output, because increases in heart rate created by left atrial pacing have been shown to increase right ventricular output and decrease left ventricular output. Since the pacemaker site could importantly influence foramen ovale flow and, hence, each ventricle's output, changes in individual ventricular outputs were examined when both the right and left atria were paced at a rate of 270 beats/min in five acute and in eight chronically instrumented fetal lamb studies. With pacing of either atrium, total cardiac output was unchanged compared to control values. However, the right ventricle contributed more to total cardiac output with left atrial pacing (73% acute, 65% chronic) than with right atrial pacing (51% acute, 57% chronic). Converse changes were observed in left atrial pacing (27% acute, 35% chronic) as compared to right atrial pacing (49% acute, 43% chronic). Thus the disparity that exists normally in the contributions of the right and left ventricles to total cardiac output is accentuated with left atrial pacing and minimized with right atrial pacing. Pressure measurements demonstrated changes in the atrial pressure relations that would be expected to alter flow across the foramen ovale depending on the chamber initially activated. Previous experimental differences can, therefore, be attributed to changes in the magnitude of shunting across the foramen ovale and depend on pacemaker location.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 1976 by the American Physiological Society.