1 Department of Physiology and Pharmacology, State University of South Dakota Medical School, Vermillion, South Dakota
A direct method is presented for the continuous quantitative measurement of blood flow in various areas of the small and large intestine. The mean blood flows of the duodenum, jejunum, ileum and descending colon were 1.39, 0.98, 0.83 and 0.73 ml/gm wet tissue/min. The cannulation of the intestinal artery to any intestinal area does not appear to interfere with the blood flow or pressure to the area. With proper precautions, a preparation will last 5 hours before measurable changes in blood flow and pressure occur.
Submitted on October 15, 1959
This article has been cited by other articles:
![]() |
A Karim, S Ahmed, L J Rossoff, R Siddiqui, A Fuchs, and A S Multz Fulminant ischaemic colitis with atypical clinical features complicating sickle cell disease Postgrad. Med. J., June 1, 2002; 78(920): 370 - 372. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. N. Kaleya and S. J. Boley Colonic Ischemia Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1991; 4(1): 121 - 137. [PDF] |
||||
![]() |
R. W. Ikard Neutropenic Typhlitis in Adults Arch Surg, July 1, 1981; 116(7): 943 - 945. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |