AJP Legacy Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol 189: 191-196, 1957;
0002-9513/57 $5.00
This Article
Right arrow Full Text (PDF)
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gerst, P. H.
Right arrow Articles by Peterson, L. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gerst, P. H.
Right arrow Articles by Peterson, L. H.

Indicator Recirculation as a Limiting Factor of Indicator Dilution Techniques

Paul H. Gerst 1, Carolyn Taylor 1, and Lysle H. Peterson 1

1 From the Department of Physiology, Medical School, University of Pennsylvania, Philadelphia, Pennsylvania

Short injections of Evans blue dye were made into the aortic root, pulmonary artery and femoral vein of dogs under normotensive and hypotensive conditions. The time intervals between the initial appearance of the indicator at the arterial sampling site and its first reappearance at the site (‘reappearance time’) were determined. Indicator concentration levels were measured simultaneously at the aortic root and femoral artery during the period of each injection. After the aortic root injections the indicator was rapidly cleared at the sampling sites so that the onset of recirculation was directly detectable from the time-concentration curve. Following pulmonary artery and femoral vein injections reappearance time was derived by the Hamilton semilogarithmic extrapolation procedure and the mean values were compared for reappearance time determined directly and indirectly. Under normotensive conditions it was found that the onset of recirculation can be adequately approximated by the Hamilton procedure when short injections are made into the pulmonary artery, but this approximation becomes less reliable in hypotension. When indicator is injected into a peripheral vein, the arterial time-concentration curve becomes so distorted that the true onset of recirculation cannot be detected by the Hamilton method. For the same injection, the mean values for reappearance times obtained at the femoral artery sampling site were greater than those obtained at the aortic root sampling site.

Submitted on July 27, 1956







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 1957 by the American Physiological Society.